C7317 (bizhub C650i/C550i/C450i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C7317: Paper exit cooling fan failure |
Rank | C |
Trouble detection condition | After starting the fan, an error is detected for the malfunction detection signal. |
Trouble isolation | – |
Relevant electrical parts | -Paper exit cooling fan (FM23) -Expansion control board (EXCB) |
Procedure
- Check the connector between FM23-relay CN710-EXCB CN15EX for proper connection and correct as necessary.
- Check the connector of FM23 for proper drive coupling and correct as necessary.
- FM23 conduction check.
- Control signal: EXCB CN15EX-4 (REM), EXCB CN15EX-6 (LOCK)
- Location of electrical component: 26-X
- Replace FM23. (Contact Konica Minolta technical support if this needs to be replaced.)
- Replace EXCB. (Part# AA2JH00500)
L.3.14.36 (Link to the Field Service Manual)