C7501 (bizhub 360i/300i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C7501: Tray 2 upper limit sensor failure |
Rank | C |
Trouble detection condition | The tray 2 upper limit sensor (PS22) does not change even after the lapse of a predetermined period of time after tray 2 is opened and closed, after C-0204 (Tray 2 feeder up/down abnormality) is detected. |
Trouble isolation | Tray 2 |
Relevant electrical parts | -Tray 2 upper limit sensor (PS22) -Base board (BASEB) |
Procedure
- Check the connector between PS22-relay CN40-BASEB CN23E for proper connection and correct as necessary.
- Replace PS22. (Part# A5C1M50100)
- Replace BASEB. (Part# AC77H02101)