How Can We Help?

C7502 (bizhub C4000i/C3300i)

You are here:

Contents

Trouble typeC7502: Tray 1 upper limit sensor failure
RankC
Trouble detection conditionThe tray 1 upper limit sensor (PS7) does not change even after the lapse of a predetermined period of time after tray 1 is opened and closed, after C0202 (Tray 1 feeder up/down abnormality) is detected.
Trouble isolationTray 1
Relevant electrical parts• Tray 1 upper limit sensor (PS7)
• Base board (BASEB)

Procedure

  1. Check the connector between PS7-BASEB CN22E for proper connection and correct as necessary.
  2. Replace PS7 (Part# A5C1M50100)
  3. Replace BASEB. (Part# AAJRH02005)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.11.14 (Link to the Field Service Manual)

Table of Contents