Trouble type | C7502: Tray 1 upper limit sensor failure |
Rank | C |
Trouble detection condition | The tray 1 upper limit sensor (PS7) does not change even after the lapse of a predetermined period of time after tray 1 is opened and closed, after C0202 (Tray 1 feeder up/down abnormality) is detected. |
Trouble isolation | Tray 1 |
Relevant electrical parts | • Tray 1 upper limit sensor (PS7) • Base board (BASEB) |
Procedure
- Check the connector between PS7-BASEB CN22E for proper connection and correct as necessary.
- Replace PS7 (Part# A5C1M50100)
- Replace BASEB. (Part# AAJRH02005)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.