How Can We Help?

C7601 (bizhub C3320i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC7601: Power line A1 error
RankC
Trouble detection conditionThe fuse detection unit detected an error for a predetermined time.
Trouble isolation
Relevant electrical parts-Main motor (M1)
-Base board (BASEB)

Procedure

  1. BASEB F18E conduction check
  2. Check the connector between M1-BASEB CN17E for proper connection and correct as necessary.
  3. M1 load check
    • Check code: 40
    • Multi code: 1, 2
    • Control signal: BASEB CN17E-1 to 5
    • Location of electrical component: 1-C
  4. Replace M1. (Part# AA2JM11000)
  5. Replace BASEB. (Part# A93EH02007)