C760A (bizhub C650i/C550i/C450i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C760A: Power line A10 error |
Rank | C |
Trouble detection condition | The fuse detection unit detected an error for a predetermined time. |
Trouble isolation | Tray 3Tray 4 |
Relevant electrical parts | -PC control board (PCCB) -Base board (BASEB) |
Procedure
- BASEB F11E conduction check
- Check the connector between PCCB CN2-relay CN65-BASEB CN29E for proper connection and correct as necessary.
- Replace PCCB. (PC-116/PC-216 / PC-416 / PC-417) (PC-116 Part# AAV5H00101 / PC-216 Part# AAV5H00201 / PC-416 (Part# AAV5H00300) / PC-417 Part# AAV5H01401)
- Replace BASEB. (Part# AA7NH02102)
L.3.14.45 (Link to the Field Service Manual)