How Can We Help?

C760C (bizhub 360i/300i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC760C: Power line A12 error
RankC
Trouble detection conditionThe fuse detection unit detected an error for a predetermined time.
Trouble isolation
Relevant electrical parts-Key counter (KCT)
-Base board (BASEB)

Procedure

  1. BASEB F13E conduction check
  2. Check the connector between KCT-relay CN119-BASEB CN3E for proper connection and correct as necessary.
  3. Replace the key counter. (Contact Konica Minolta regarding replacement)
  4. Replace BASEB. (Part# AC77H02101)

(Link to the Field Service Manual)

Table of Contents