How Can We Help?

C760F (bizhub C4000i/C3300i)

You are here:

Contents

Trouble typeC760F: Power line A15 error
RankC
Trouble detection conditionThe fuse detection unit detected an error for a predetermined time.
Trouble isolation
Relevant electrical parts• Clean unit drive board (CUDB)
• Base board (BASEB)

Procedure

  1. BASEB F11E conduction check
  2. Check the connector between CUDB CN1-relay CN35-BASEB CN25E for proper connection and correct as necessary.
  3. Replace CUDB. (Not available in the U.S.)
  4. Replace BASEB. (Part# AAJRH02005)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.11.21 (Link to the Field Service Manual)