How Can We Help?

C7613 (bizhub C4050i/C3350i)

You are here:

Contents

Trouble typeC7613: Power line A19 error
RankC
Trouble detection conditionThe fuse detection unit detected an error for a predetermined time.
Trouble isolation
Relevant electrical parts• Machine cooling fan (FM1)
• Toner suction fan (FM2)
• Base board (BASEB)

Procedure

  1. BASEB F2E conduction check
  2. Check the connector between FM1-relay CN23-BASEB CN19E for proper connection and correct as necessary.
  3. Check the connector between FM2-relay CN10-BASEB CN18E for proper connection and correct as necessary.
  4. Replace FM1. (Part# A93EM10000)
  5. Replace FM2. (Part# A93EM10600)
  6. Replace BASEB. (Part# A93EH02007)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.12.22 (Link to the Field Service Manual)

Table of Contents