How Can We Help?

C7616 (bizhub C4050i/C3350i)

You are here:

Contents

Trouble typeC7616: Power line A21 error
RankC
Trouble detection conditionThe fuse detection unit detected an error for a predetermined time.
Trouble isolation
Relevant electrical parts• Toner supply motor/YM (M4)
• Toner supply motor/CK (M5)
• Base board (BASEB)

Procedure

  1. BASEB F5E conduction check
  2. Check the connector between M4-BASEB CN13E for proper connection and correct as necessary.
  3. Check the connector between M5-BASEB CN13E for proper connection and correct as necessary.
  4. Replace M4. (Part# A7PUM10700)
  5. Replace M5. (Part# A7PUM10700)
  6. Replace BASEB. (Part# A93EH02007)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.12.24 (Link to the Field Service Manual)

Table of Contents