C7622 (bizhub C650i/C550i/C450i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC7622: Power line B2 error
RankC
Trouble detection conditionThe fuse detection unit detected an error for a predetermined time.
Trouble isolation
Relevant electrical parts-PH unit
-Expansion control board (EXCB)

Procedure

  1. EXCB ICP1 or ICP3 conduction check.
  2. Check the connector between the PH unit-relay CN306-EXCB CN10EX for proper connection and correct as necessary.
  3. Check the connector between the PH unit-relay CN300-EXCB CN7EX for proper connection and correct as necessary.
  4. Replace the PH unit. (C650i/C550i Part# AA7NR70500 / C450i Part# AA7RR70100)
  5. Replace EXCB. (Part# AA2JH00500)

L.3.14.52 (Link to the Field Service Manual)