C762D (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C762D: Power line B13 error |
Rank | C |
Trouble detection condition | The fuse detection unit detected an error for a predetermined time. |
Trouble isolation | – |
Relevant electrical parts | – Reverse paper cooling fan/1 (FM4) – Reverse paper cooling fan/2 (FM5) – Paper feed/transport drive board (PFTDB) |
Procedure
- PFTDB F41 conduction check.
- Check the connector between FM4-relay CN699-relay CN280-relay CN271A-PFTDB CN27 for proper connection and correct as necessary.
- Check the connector between FM5-relay CN700-relay CN280-relay CN271A-PFTDB CN27 for proper connection and correct as necessary.
- FM4 load check
- Check code: 42
- Multi code: 14, 15
- Control signal: PFTDB CN27-1 to 3
- Location of electrical component: 7-P
- Replace FM4.
- FM5 load check
- Check code: 42
- Multi code: 16, 17
- Control signal: PFTDB CN27-5 to 7
- Location of electrical component: 7-P
- Replace FM5.
- Replace PFTDB.