How Can We Help?

C7631 (bizhub 360i/300i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC7631: Supply power line 1 error
RankC
Trouble detection conditionAll of the fuse detection units of the same supply power line (24V11) detected an error for a predetermined time.
Trouble isolation
Relevant electrical parts-DC power supply (DCPU)
-Expansion control board (EXCB)
-Base board (BASEB)

Procedure

  1. BASEB F11E, F12E, F13E, F14E, F15E, F17E conduction check
  2. Check the connector between DCPU CN4, CN7-BASEB CN14E for proper connection and correct as necessary.
  3. Check the connector between BASEB CN11E-EXCB CN1EX for proper connection and correct as necessary.
  4. Replace BASEB. (Part# AC77H02101)
  5. Replace EXCB. (Part# AC77H00501)
  6. Replace DCPU. (Part# AA2JR74000)

(Link to the Field Service Manual)