Trouble typeC7632: Supply power line 2 error
RankC
Trouble detection conditionAll of the fuse detection units of the same supply power line (24V21) detected an error for a predetermined time.
Trouble isolation
Relevant electrical parts-DC power supply (DCPS)
-Base board (BASEB)

Procedure

  1. BASEB F5E, F6E, F20E conduction check
  2. Check the connector between DCPS CN4-BASEB CN3E for proper connection and correct as necessary.
  3. Check the connector between DCPS CN6-BASEB CN1E for proper connection and correct as necessary.
  4. Check the connector between SW2, SW5-relay CN36-DCPS CN3 for proper connection and correct as necessary.
  5. Replace DCPS. (Part# AAJRR70600)
  6. Replace BASEB.
    4750i (Part# ACT9H02013)
    4050i (Part# ACT9H02002)