How Can We Help?

C7632 (bizhub C4050i/C3350i)

You are here:

Contents

Trouble typeC7632: Supply power line 2 error
RankC
Trouble detection conditionAll of the fuse detection units of the same supply power line (24V21) detected an error for a predetermined time.
Trouble isolation
Relevant electrical parts• DC power supply (DCPS)
• Base board (BASEB)

Procedure

  1. BASEB F5E, F6E, F20E conduction check
  2. Check the connector between DCPS CN4-BASEB CN3E for proper connection and correct as necessary.
  3. Check the connector between DCPS CN6-BASEB CN1E for proper connection and correct as necessary.
  4. Check the connector between SW2, SW5-relay CN36-DCPS CN3 for proper connection and correct as necessary.
  5. Replace DCPS. (Part# AAJRR70600)
  6. Replace BASEB. (Part# A93EH02007)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.12.26 (Link to the Field Service Manual)

Table of Contents