C7633 (bizhub C4000i/C3300i)

You are here:

Contents

Trouble typeC7633: Supply power line 3 error
RankC
Trouble detection conditionAll of the fuse detection units of the same supply power line (24V20) detected an error for a predetermined time.
Trouble isolation
Relevant electrical parts• DC power supply (DCPS)
• Base board (BASEB)

Procedure

  1. BASEB F8E, F11E, F18E, F19E conduction check
  2. Check the connector between DCPS CN4-BASEB CN3E for proper connection and correct as necessary.
  3. Check the connector between DCPS CN6-BASEB CN1E for proper connection and correct as necessary.
  4. Check the connector between SW2, SW5-relay CN36-DCPS CN3 for proper connection and correct as necessary.
  5. Replace DCPS. (Part# AAJRR70600)
  6. Replace BASEB. (Part# AAJRH02005)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.11.27 (Link to the Field Service Manual)