How Can We Help?

C8101 (bizhub 287/227)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC8101: Before reading pressure welding alienation mechanism (When DF-628 is installed)
RankB
Trouble detection condition-During a pressure motion being performed, the reading roll position sensor (PS11) output does not change from H to L.
-During a retraction motion being performed, the reading roll position sensor (PS11) output does not change from L to H.
Trouble isolationDF
Relevant electrical parts-Reading roll release motor (M5)
-Reading roll position sensor (PS11)
-DF control board (DFCB)

 Procedure

  1. Check the connector between M5-DFCB J18 for proper connection and correct as necessary.
  2. Check the connector of M5 for proper drive coupling and correct as necessary.
  3. Check the connector between PS11-DFCB J18 for proper connection and correct as necessary.
  4. PS11 I/O check, sensor check
    • Control signal: DFCB J18-3 (ON)
    • Location of electrical component: DF-628 1-G
  5. M5 operation check
    • Control signal: DFCB J18-4 to 5
    • Location of electrical component: DF-628 2-G
  6. Replace M5. (Part# A3CFPP6J00)
  7. DFCB F9 conduction check.
  8. Replace DFCB. (Part# A7V7PP0000)

NOTICE

  • Link to the wiring diagram (DF-628)

K.3.14.1 (Link to the Field Service Manual)

Table of Contents