C8101 (bizhub 368e/308e)
Contents
Trouble type | C8101: Before reading pressure welding alienation mechanism (When DF-629 or DF-704 is installed) | |
Rank | B | |
Trouble detection condition | <When DF-629 is installed> • During a pressure motion being performed, the reading roll position sensor (PS11) output does not change from H to L. • During a retraction motion being performed, the reading roll position sensor (PS11) output does not change from L to H. | |
<When DF-704 is installed> • During a pressure motion being performed, the reading roll position sensor (PS4) output does not change from H to L. • During a retraction motion being performed, the reading roll position sensor (PS4) output does not change from L to H. | ||
Trouble isolation | – | |
Relevant electrical parts | <When DF-629 is installed> • Reading roll release motor (M5) • Reading roll position sensor (PS11) • DF control board (DFCB) | |
<When DF-704 is installed> • Reading roll release motor (M4) • Reading roll position sensor (PS4) • DF control board (DFCB) |
Procedure
When DF-629 is installed
- Check the connector between M5-DFCB J18 for proper connection and correct as necessary.
- Check the connector of M5 for proper drive coupling and correct as necessary.
- Check the connector between PS11-DFCB J18 for proper connection and correct as necessary.
- PS11 I/O check, sensor check
- Control signal: DFCB J18-3 (ON)
- Location of electrical component: DF-629 1-G
- M5 load check
- Check code: 60
- Multi code: 81, 82
- Control signal: DFCB J18-4 to 5
- Location of electrical component: DF-629 2-G
- Replace M5. (Part# A3CFPP6J00)
- Replace DFCB. (Part# A87RPP1700)
When DF-704 is installed
- Check the connector between M4-DFCB J18 for proper connection and correct as necessary.
- Check the connector of M4 for proper drive coupling and correct as necessary.
- Check the connector between PS4-DFCB J18 for proper connection and correct as necessary.
- PS4 I/O check, sensor check
- Control signal: DFCB J18-3 (ON)
- Location of electrical component: DF-704 1-G
- M4 load check
- Check code: 60
- Multi code: 81, 82
- Control signal: DFCB J18-4 to 5
- Location of electrical component: DF-704 1-G
- Replace M4. (Part# A3CEPP5700)
- Replace DFCB. (Part# A85GPP0M00)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.19.1 (Link to the Field Service Manual)