How Can We Help?

C8101 (bizhub C368/C308/C258)

You are here:

C8101 (bizhub C368/C308/C258)

Contents

Trouble typeC8101: Before reading pressure welding alienation mechanism (When DF-629 or DF-704 is installed)
RankB
Trouble detection condition<When DF-629 is installed>
• During a pressure motion being performed, the document reading sensor (PS4) output does not change from H to L.
• During a retraction motion being performed, the document reading sensor (PS4) output does not change from L to H.
• During a pressure motion being performed, the document reading sensor (PS6) output does not change from H to L.
• During a retraction motion being performed, the document reading sensor (PS6) output does not change from L to H.
Trouble isolation
Relevant electrical parts<When DF-629 is installed>
• Reading roll release motor (M5)
• Document reading sensor (PS4)
• DF control board (DFCB)
• Reading roller release motor (M4)
• Document reading sensor (PS6)
• DF control board (DFCB)

Procedure

When DF-629 is installed

  1. Check the connector between M5-DFCB J18 for proper connection and correct as necessary.
  2. Check the connector of M5 for proper drive coupling and correct as necessary.
  3. Check the connector between PS4-DFCB J10 for proper connection and correct as necessary.
  4. PS4 I/O check, sensor check
    • Control signal: DFCB J10-3 (ON)
    • Location of electrical component: DF-629 2-G
  5. M5 operation check
    • Control signal: DFCB J18-4 to 5
    • Location of electrical component: DF-629 2-G
  6. Replace M5. Part# A3CFPP6J00
  7. Replace DFCB. (Part# A87RPP1700)

NOTICE

  • Link to the wiring diagram (DF-629)

When DF-704 is installed

  1. Check the connector between M4-DFCB J18 for proper connection and correct as necessary.
  2. Check the connector of M4 for proper drive coupling and correct as necessary.
  3. Check the connector between PS6-DFCB J10 for proper connection and correct as necessary.
  4. PS6 I/O check, sensor check
    • Control signal: DFCB J10-3 (ON)
    • Location of electrical component: DF-704 2-G
  5. M4 operation check
    • Control signal: DFCB J18-4 to 5
    • Location of electrical component: DF-704 1-G
  6. Replace M4. Part# A3CEPP5700
  7. Replace DFCB. (Part# A85GPP0M00)

NOTICE

  • Link to the wiring diagram (DF-704)