How Can We Help?

C8101 (bizhub C754e/C654e)

You are here:

Contents

Trouble typeBefore reading pressure/retraction alienation mechanism
Trouble codeC8101
RankB
Detection timing• During a pressure motion being performed, the read roller home sensor (PS8) output does not change from H to L.
• During a retraction motion being performed, the read roller home sensor (PS8) output does not change from L to H.
Trouble isolation
Relevant electrical parts• Reading roller pressure/retraction motor (M6)
• Read roller home sensor (PS8)
• DF control board (DFCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M6-DFCB CN4 for proper connection, and correct as necessary.
2Check the connector of M6 for proper drive coupling, and correct as necessary.
3Check the connector between PS8-DFCB CN4 for proper connection, and correct as necessary.
4PS8 I/O check, sensor checkDFCB CN4-18 (ON)DF-702 10-C
5M6 operation checkDFCB CN4-20 (ON)DF-702 10-C
6Replace M6 (Part# A2X0R70H11)
7DFCB ICP9 conduction check
8Replace DFCB (Part# A3CKH00102)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.12.1 (Link to the Field Service Manual)

Table of Contents