C8107 (bizhub 558/458)
Contents
Trouble type | C8107: Glass cleaning mechanism trouble |
Rank | B |
Trouble detection condition | The document reading glass cleaning sensor (PS13) is not turned ON after the set period of time has elapsed after the document reading glass cleaning motor (M6) is turned ON. |
Trouble isolation | – |
Relevant electrical parts | • Document reading glass cleaning motor (M6) • Document reading glass cleaning sensor (PS13) • DF control board (DFCB) |
Procedure
- Check the connector between M6-DFCB J8 for proper connection and correct as necessary.
- Check the connector of M6 for proper drive coupling and correct as necessary.
- Check the connector between PS13-DFCB J15 for proper connection and correct as necessary.
- PS13 I/O check, sensor check
- Control signal: DFCB J15-5 (ON)
- Location of electrical component: DF-704 3-G
- M6 operation check
- Control signal: DFCB J8-1 to 4
- Location of electrical component: DF-704 1-B
- Replace M6. (Part# A3CFPP5R00)
- Replace DFCB. (Part# A85GPP0M00)
NOTICE
- Link to the wiring diagram (DF-704)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.21.2 (Link to the Field Service Manual)