How Can We Help?

C8107 (bizhub C287/C227)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC8107: Glass cleaning mechanism trouble (When DF-628 is installed)
RankB
Trouble detection conditionThe original reading glass cleaning sensor (PS12) is not turned ON after the set period of time has elapsed after the glass cleaning motor (M4) is turned ON.
Trouble isolationDF
Relevant electrical parts-Glass cleaning motor (M4)
-Original reading glass cleaning sensor (PS12)
-DF control board (DFCB)

 Procedure

  1. Check the connector between M4-DFCB J8 for proper connection and correct as necessary.
  2. Check the connector of M4 for proper drive coupling and correct as necessary.
  3. Check the connector between PS12-DFCB J15 for proper connection and correct as necessary.
  4. PS12 I/O check, sensor check
    • Control signal: DFCB J15-5 (ON)
    • Location of electrical component: DF-628 3-G
  5. M4 operation check
    • Control signal: DFCB J8-1 to 4
    • Location of electrical component: DF-628 1 to 2-B
  6. Replace M4. (Part# A3CFPP5R00)
  7. Replace DFCB. (Part# A7V7PP0000)

NOTICE

  • Link to the wiring diagram (DF-628)

K.3.14.2 (Link to the Field Service Manual)

Table of Contents