C8302 (bizhub 368e/308e)
Contents
Trouble type | C8302: Cooling fan trouble (When DF-629 or DF-704 is installed) | |
Rank | B | |
Trouble detection condition | <When DF-629 is installed> The lock signal continues to detect H during a given time while the DF cooling fan motor (FM1) is spinning.The lock signal continues to detect L during a given time while the DF cooling fan motor (FM1) is during halts. | |
<When DF-704 is installed> The lock signal continues to detect H during a given time while the DF cooling fan motor (FM1) is spinning.The lock signal continues to detect L during a given time while the DF cooling fan motor (FM1) is during halts. | ||
Trouble isolation | – | |
Relevant electrical parts | <When DF-629 is installed> • DF cooling fan motor (FM1) • DF control board (DFCB) | |
<When DF-704 is installed> • DF cooling fan motor (FM1) • DF control board (DFCB) |
Procedure
When DF-629 is installed
- Check the connector between FM1-DFCB J16 for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- FM1 load check
- Check code: 60
- Multi code: 113
- Control signal: DFCB J16-3 (ON)
- Location of electrical component: DF-629 3-B
- Replace FM1. (Part# Not in Parts manual)
- Replace DFCB. (Part# A87RPP1700)
When DF-704 is installed
- Check the connector between FM1-DFCB J16 for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- FM1 load check
- Check code: 60
- Multi code: 113
- Control signal: DFCB J16-3 (ON)
- Location of electrical component: DF-704 7-G
- Replace FM1. (Part# A143PP0200)
- Replace DFCB. (Part# A85GPP0M00)