How Can We Help?

C8302 (bizhub 4750i/4050i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC8302: DF cooling fan trouble
RankB
Trouble detection conditionThe lock signal continues to detect H during a given time while the DF cooling fan (FM4) is spinning.
Trouble isolationDF
Relevant electrical parts-DF cooling fan (FM4)
-DF control board (DFCB)

Procedure

  1. Check the connector between FM4-relay CN112-DFCB CN4 for proper connection and correct as necessary.
  2. Check the fan for possible overload and correct as necessary.
  3. FM4 load check
    • Check code: 60
    • Multi code: 113
    • Control signal: DFCB CN4-5 (REM), DFCB CN4-7 (LOCK)
    • Location of electrical component: 22-X
  4. Replace FM4. (Part# 9J06M10000)
  5. Replace DFCB. (Part# A93EH00901)

(Link to the Field Service Manual)

Table of Contents