How Can We Help?

C8302 (bizhub 554e/454e)

You are here:

(1)Contents

Trouble typeCooling fan trouble
Trouble codeC8302
RankB
Detection timing• The lock signal continues to detect H during a given time while the DF cooling fan motor (FM1) is spinning.
• The lock signal continues to detect L during a given time while the cooling fan (FM1) is during halts.
Trouble isolation
Relevant electrical parts• DF cooling fan motor (FM1)
• DF control board (DFCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between FM1-DFCB J16 for proper connection and correct as necessary.
2Check the fan for possible overload and correct as necessary.
3FM1 operation checkDFCB J16-3 (ON)DF-701 7-G
4Replace FM1 (Part# 4139M10000)
5DFCB F6 conduction check
6Replace DFCB (Part# A3CEPP4900)
  • Link to the wiring diagram (N.2. DF-701)
  • Link to the layout drawings for related parts by each trouble code (S.110. C8302)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.12.3 (Link to the Field Service Manual)

Table of Contents