C8302 (bizhub 754e/654e)
Contents
Trouble type | Take-up cooling fan failure |
Trouble code | C8302 |
Rank | B |
Detection timing | While the motor is running, the fan lock signal remains HIGH for a predetermined number of times in a row. |
Trouble isolation | – |
Relevant electrical parts | • Take-up cooling fan (FM1) • DF control board (DFCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector of FM1-DFCB CN9 for proper connection and correct as necessary. | – | – |
2 | Check the fan for possible overload and correct as necessary. | – | – |
3 | FM1 operation check | DFCB CN9-9 (LOCK) | DF-702 4-C |
4 | Replace FM1 | – | – |
5 | DFCB ICP5 conduction check | – | – |
6 | Replace DFCBDFCB (Part# A3CKH00102) | – | – |
- Link to the wiring diagram (N.2.1 Reverse automatic document feeder DF-702)
- Link to the layout drawings for related parts by each trouble code (S.106. C8302)