C8302 (bizhub C4050i/C3350i)
Contents
Trouble type | C8302: DF cooling fan trouble |
Rank | B |
Trouble detection condition | The lock signal continues to detect H during a given time while the DF cooling fan motor (FM4) is spinning. |
Trouble isolation | DF |
Relevant electrical parts | DF cooling fan motor (FM4)DF control board (DFCB) |
Procedure
- Check the connector between FM4-relay CN112-DFCB CN4 for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- FM4 load check
- Check code: 60
- Multi code: 113
- Control signal: DFCB CN4-5 (REM), DFCB CN4-7 (LOCK)
- Location of electrical component: 22-X
- Replace FM4. (Part# 9J06M10000)
- Replace DFCB. (Part# A93EH00901)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.13.1 (Link to the Field Service Manual)