C8302 (bizhub C658/C558/C458)

You are here:

Contents

Trouble typeC8302: Cooling fan motor’s failure
RankB
Trouble detection conditionThe motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Trouble isolationDF
Relevant electrical parts• Cooling fan motor (FM)
• DF control board (DFCB)

 Procedure

  1. Check the connector between FM-relay CN115-DFCB CN19 for proper connection and correct as necessary.
  2. Check the fan for possible overload and correct as necessary.
  3. FM operation check
    • Control signal: DFCB CN19-3 (LOCK)
    • Location of electrical component: DF 4-C
  4. Replace FM. (Part# 4556M10000)
  5. DFCB ICP10 conduction check.
  6. Replace DFCB. (Part# A782H0010A)

NOTICE

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.20.5 (Link to the Field Service Manual)