How Can We Help?
C8402 (bizhub C750i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C8402: Multi feed detection board failure |
Rank | C |
Trouble detection condition | When the main power switch ON or when the original is being conveyed, the AD value there is no paper loaded state is out of the predetermined range. |
Trouble isolation | DF |
Relevant electrical parts | -Multi feed detection board/TX (MFDB/TX) -Multi feed detection board/RX (MFDB/RX) -DF control board (DFCB) |
Procedure
- Check the connector between MFDB/TX-relay CN114-DFCB CN23 for proper connection and correct as necessary.
- Check the connector between MFDB/RX-DFCB CN22 for proper connection and correct as necessary.
- MFDB/TX operation check
- Control signal: DFCB CN23-1 to 3
- Location of electrical component: DF 11-J
- MFDB/RX operation check
- Control signal: DFCB CN22-1 to 4
- Location of electrical component: DF 10-J
- Replace DFCB. (Part# AAMPH00105)