C9401, C9402 (bizhub 4750i/4050i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C9401: CIS LED lighting failure (front side) C9402: CIS LED lighting abnormally (front side) |
Rank | B |
Trouble detection condition | C9401: At the CIS gain adjustment, the machine detected that the output of the CIS LED is lower than the specified value. C9402: The average output value of the CIS LED with the scanner at its standby position is a predetermined value or more at the end of a scan job. |
Trouble isolation | Scanner |
Relevant electrical parts | -Flat cable -CIS module (IR CIS) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Check the connector between IR CIS-BASEB CN6 for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Replace the flat cable.
- Replace IR CIS. (Part# AAJNR71200)
- Replace CPUB. (Part# ACT9H01003)
- Replace BASEB.
4750i (Part# ACT9H02013)
4050i (Part# ACT9H02002)