Trouble typeC9401: Exposure LED lighting failure

C9402: Exposure LED lighting abnormally
RankB
Trouble detection conditionC9401: The output from the CCD sensor is a predetermined value or less during CCD sensor gain adjustment.

C9402: The average output value of the CCD sensor with the scanner at its standby position is a predetermined value or more at the end of a scan job.
Trouble isolationScanner
Relevant electrical parts-LED exposure unit
-Flat cable (LED exposure unit)
-CCD unitScanner drive board (SCDB)
-CPU board (CPUB)
-Base board (BASEB)

Procedure

  1. Correct the harness connection between SCDB CN3-LU201 if faulty.
  2. Check the connector between SCDB CN2-BASEB CN6E for proper connection and correct as necessary.
  3. Check the connector between CCDB CN2-BASEB CN6 for proper connection and correct as necessary.
  4. Check CPUB for proper installation and correct as necessary.
  5. Replace the LED exposure unit. (Part# AA7NM31200)
  6. Replace the CCD unit. (Part# AA7NR72500)
  7. SCDB ICP2 conduction check
  8. Replace SCDB. (Part# AA7NH01A00)
  9. Replace CPUB.
    650i/550i (Part# AC74H02P03)
    450i (Part# AC76H02P02)
  10. Replace BASEB. (Part# AC74H02101)