How Can We Help?

C9401,C9402 (bizhub 950i/850i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble type– C9401: Exposure LED lighting failure

– C9402: Exposure LED lighting abnormally
RankB
Trouble detection condition– C9401: The output from the CCD sensor is a predetermined value or less during CCD sensor gain adjustment.

– C9402: The average output value of the CCD sensor with the scanner at its standby position is a predetermined value or more at the end of a scan job.
Trouble isolationScanner
Relevant electrical parts– LED exposure unit
– Flat cable (LED exposure unit)
– CCD unit
– Scanner drive board (SCDB)
– CPU board (CPUB)
– Base board (BASEB)

Procedure

  1. Correct the harness connection between SCDB CN3-LU201 if faulty.
  2. Check the connector between SCDB CN2-BASEB CN1E for proper connection and correct as necessary.
  3. Check the connector between CCDB CN2-BASEB CN6 for proper connection and correct as necessary.
  4. Check CPUB for proper installation and correct as necessary.
  5. Replace the LED exposure unit.
  6. Replace the CCD unit.
  7. SCDB ICP2 conduction check.
  8. Replace SCDB.
  9. Replace CPUB.
  10. Replace BASEB.

(Link to the Field Service Manual)

Table of Contents