How Can We Help?

C9402 (bizhub 287/227)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC9402: Exposure LED lighting abnormally
RankB
Trouble detection conditionThe average output value of the CCD sensor with the scanner at its standby position is a predetermined value or more at the end of a scan job.
Trouble isolationScanner
Relevant electrical parts-LED exposure unit
-CCD unitFlat cable (CCD unit)
-CCD board (CCDB)
-MFP board (MFPB)

 Procedure

  1. Update the firmware to the function version 4.0 or later.
  2. Check the connector between LEDB CN1-CCDB PJ7 for proper connection and correct as necessary.
  3. Check the connector between CCDB PJ1-MFPB CN7 for proper connection and correct as necessary.
  4. Replace the LED exposure unit. (Part# A890R70211)
  5. Replace the CCD unit. (Part# A890R70033Old or A890R70300)
  6. MFPB F8E conduction check
  7. Replace MFPB. (Part# A7AHH0201D)

K.3.15.1 (Link to the Field Service Manual)

Table of Contents