C9402 (bizhub 658e/558e/458e)
Contents
Trouble type | C9402: Exposure LED lighting abnormally |
Rank | B |
Trouble detection condition | C9402: The average output value of the CCD sensor with the scanner at its standby position is a predetermined value or more at the end of a scan job. |
Trouble isolation | Scanner |
Relevant electrical parts | •LED exposure unit • Flat cable (LED exposure unit) • CCD board (CCDB) • Scanner drive board (SCDB) • MFP board (MFPB) |
Procedure
- Correct the harness connection between SCDB CN3-LU201 if faulty.
- Check the connector between SCDB CN2-MFPB CN6E for proper connection and correct as necessary.
- Check the connector between CCDB PJ3-MFPB CN1 for proper connection and correct as necessary.
- Replace the LED exposure unit. (Part# A7PUR71000)
- Replace CCDB. (Part # A795R71000)
- Replace SCDB. ( Part # A796H01A00)
- Replace MFPB. (658e/558e)(Part# AA6RH02103 ) ( 458e )(Part # AA6UH02101 )
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
(Link to the Field Service Manual) L.3.22.1.