Trouble typeC9403: CIS LED lighting failure

C9404: CIS LED lighting abnormally
RankB
Trouble detection conditionC9403: At the CIS gain adjustment, the machine detected that the output of the CIS LED is lower than the specified value.

C9404: After a scan job is completed, the machine detected that the average output of the CIS LED is greater than the specified value.
Trouble isolationScanner
Relevant electrical parts-CIS cable
-CIS module (CIS)
-CIS power supply (CISPU)
-CPU board (CPUB)
-Base board (BASEB)

Procedure

  1. Check the back side scanning shading shaft for any stain, and clean up it as necessary.
  2. Check that the bushing of the back side glass cleaning roller unit is on the standby position.
  3. Correct the harness connection between CIS CN2-BASEB CN5 if faulty.
  4. Correct the harness connection between CIS CN1-CISPU CN2 if faulty.
  5. Check CPUB for proper installation and correct as necessary.
  6. Measure the voltage of CISPU CN1-2.
    • Control signal: CISPU CN1-2 (DC12V)
    • Location of electrical component: DF 4-I
  7. Measure the voltage of CIS CN1-1, CN1-2 and CN1-5.
    • Control signal: CIS CN1-1 (DC5V), CIS CN1-2 (DC5V), CIS CN1-5 (DC12V)
    • Location of electrical component: DF 5-I
  8. For any abnormality in the measurement result, replace the CIS cable.
  9. Replace CIS. (Part# AAMPR70100)
  10. Replace CISPU. (Part# A3CKH00200)
  11. Replace CPUB. (Part# ACV7H02P02)
  12. Replace BASEB. (Part# ACV7H02101)