C9404 (bizhub C554e/C454e)

You are here:

Contents

Trouble typeCIS LED lighting abnormally
Trouble codeC9404
RankA
Detection timingAfter a scan job is completed, the machine detected that the average output of the CIS LED is greater than the specified value.
Trouble isolationScanner
Relevant electrical parts• CIS module (CIS) 
• CIS power supply (CISPU) 
• Dual scan image processing board (DSIPB) 
• MFP board (MFPB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the back side scanning shading shaft for any stain, and clean up it as necessary.
2Check that the bearing of the back side glass cleaning roller unit is on the standby position.
3Correct the harness connection between CIS and DSIPB if faulty.
4Correct the harness connection between CIS and CISPU if faulty.
5Measure the voltage of CISPU J1-1.CISPU J1-1 (DC12V)DF-701 5-B
6Measure the voltage of CIS J222-1, J222-2 and J222-5.CIS J222-1 (DC5V)CIS J222-2 (DC5V)CIS J222-5 (DC12V)DF-701 4-B
7For any abnormality in the measurement result, replace the CIS cable. (A3CEN11711 or A3CEN11700Old)
8Replace CIS (Part# A3CEM70000)
9CISPU F1, F2 conduction check
10Replace CISPU (Part# A3CEPP4Y00)
11Replace DSIPB (Part# A5C1H02A01)
12Replace MFPB (Part #A5C1H0200B)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.13.2 (Link to the Field Service Manual)