How Can We Help?
CA051 (bizhub C658/C558/C458/C368/C308/C258)
Contents
Trouble type | CA051: Standard controller configuration failure |
Rank | C |
Trouble detection condition | The controller of the MFP board (MFPB) is faulty. |
Trouble isolation | – |
Relevant electrical parts | MFP board (MFPB) |
Procedure
- Check to see if the following setting has been correctly made: [Service Mode] -> [System 2] -> [Image Controller Setting].
- If changing the setting, turn OFF the main power switch and turn it ON again after 10 seconds or more.
- Check the connectors of the MFPB for proper connection and correct as necessary.
- Replace MFPB. (bizhub C368/C308/C258 (Part# A7PUH02123) / bizhub C658/C558/C458 (C458 Part# A79MH02102 / C558 or C658 Part # A79JH02102))
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.22.1 (Link to the Field Service Manual)