How Can We Help?

CA051, CA052, CA053 (bizhub 360i/300i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeCA051: Standard controller configuration failure

CA052: Controller hardware error

CA053: Controller start failure
RankC
Trouble detection conditionCA051: The controller of the CPU board (CPUB) is faulty.

CA052: A controller hardware error is detected in the network interface.

CA053: A controller start failure is detected in the controller interface.
Trouble isolation
Relevant electrical parts-CPU board (CPUB)
-Base board (BASEB)

Procedure

  1. Check to see if the following setting has been correctly made: [Service Mode] -> [System 2] -> [Image Controller Setting].
  2. If changing the setting, turn OFF the main power switch and turn it ON again after 10 seconds or more.
  3. Check the connectors on BASEB for proper connection and correct as necessary.
  4. Replace CPUB. (Part# AC77H02P02)
  5. Replace BASEB. (Part# AC77H02101)

(Link to the Field Service Manual)