How Can We Help?

CA052 (958/808)

You are here:

Contents

Trouble typeCA052: Controller hardware error
RankC
Trouble detection conditionCA052: A controller hardware error is detected in the network interface.
Trouble isolation
Relevant electrical partsMFP board (MFPB)

Procedure

  1. Check to see if [Service Mode] -> [System 2] -> [Image Controller Setting] has been set to Controller 0. If changing the setting, turn OFF the main power switch and turn it ON again after 10 seconds or more.
  2. Check the connectors of the MFPB for proper connection and correct as necessary.
  3. Replace MFPB. (Part# A796H02015 )