Trouble typeController hardware error
Trouble codeCA052
RankC
Detection timingA controller hardware error is detected in the network interface.
Trouble isolation
Relevant electrical partsMFP board (MFPB)

(2)Procedure

StepActionControl signalLocation of electrical components
1Check to see if the following setting has been correctly made: [Service Mode] -> [System 2] -> [Image Controller Setting].If changing the setting, turn OFF the main power switch and turn it ON again after 10 seconds or more.
2Check the connectors of the MFPB for proper connection and correct as necessary.
3Replace MFPB (Part# A2XKH02004)

K3.14.1 (Link to the Field Service Manual)