CA052 (bizhub C554/C454)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | Controller hardware error |
Trouble code | CA052 |
Rank | C |
Detection timing | A controller hardware error is detected in the network interface. |
Trouble isolation | – |
Relevant electrical parts | MFP board (MFPB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check to see if the following setting has been correctly made: [Service Mode] -> [System 2] -> [Image Controller Setting].If changing the setting, turn OFF the main power switch and turn it ON again after 10 seconds or more. | – | – |
2 | Check the connectors of the MFPB for proper connection and correct as necessary. | – | – |
3 | Replace MFPB (Part# A2XKH02004) | – | – |
- Link to the layout drawings for related parts by each trouble code (S.103. C5372, C6901- C6903, CA051 – CA053, CC151, CC152, CC170 – CC186, CC191 – CC214, CC216, CD211, CD212, CD241, CD242, CD252 – CD271, CD401- CD412, CE001, CE003 – CE007, CE101, CE201, CE301 – CEEE1)
K3.14.1 (Link to the Field Service Manual)