C2A14 (bizhub 650i/550i/450i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C2A14: Drum unit/K new release failure |
Rank | B |
Trouble detection condition | The status with the new unit is not cleared after the new drum unit is set. |
Trouble isolation | – |
Relevant electrical parts | -Drum unit/K -Expansion control board (EXCB) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Clean the connection between the drum unit and the main body if dirty.
- Reinstall the drum unit.
- Check the connector between the drum unit/K-relay CN48-relay CN149-EXCB CN4EX for proper connection and correct as necessary.
- Check the connector between EXCB CN1EX-BASEB CN11E for proper connection and correct as necessary.
- Check the connector between EXCB CN2EX-BASEB CN12E for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Replace the drum unit. (Part# ACV80RD)
- Replace EXCB. (Part# AC74H00501)
- Replace CPUB.
650i/550i(Part# AC74H02P03)
450i (Part# AC76H02P02) - Replace BASEB. (Part# AC74H02101)