How Can We Help?

CC159 (bizhub 364e/284e/224e)

You are here:

Contents

Trouble type ROM contents error upon startup (DSC1), ROM contents error upon startup (DSC2)
Trouble code CC159
Rank C
Detection timing A fault is detected in a sequence of ROM contents check of the DSC board during starting.
Trouble isolation
Relevant electrical parts • DSC board/1 (DSCB/1; SC-508)
• DSC board/2 (DSCB/2; SC-508: only when DF-701 is installed)

  (2)Procedure

Step Action Control signal Location of electrical components
1 Check DSCB/1 or DSCB/2 connector for proper connection and correct as necessary.
2 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch.
3 Rewrite the firmware.
4 Replace DSCB/1 or DSCB/2 (SC-508 Not sold in the U.S.) Contact Konica Minolta technical support if this needs to be replaced.

Document Information ID D0001127958 Revise ID R000002