Trouble type | CC15B: Flash ROM error (saddle) (When FS-539SD or FS-540SD is installed) |
Rank | C |
Trouble detection condition | Data of flash ROM of the saddle is determined to be faulty when the main power switch is turned ON. |
Trouble isolation | – |
Relevant electrical parts | SD control board (SDCB) |
Procedure
- Turn OFF the main power switch and unplug the power cord. Connect the power cord after 15 sec. or more, and turn ON the main power switch.
- Rewrite the firmware.
- Replace SDCB. (FS-539SD / FS-540SD)(Part# A3ERPP6J03)