CC170, CC171, CC172, CC173, CC174, CC180, CC181, CC182, CC183, CC184, CC185, CC186 (bizhub 650i/550i/450i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | CC170: Dynamic link error during starting (AP0) CC171: Dynamic link error during starting (AP1) CC172: Dynamic link error during starting (AP2) CC173: Dynamic link error during starting (AP3) CC174: Dynamic link error during starting (AP4) CC180: Dynamic link error during starting (LDR) CC181: Dynamic link error during starting (IBR) CC182: Dynamic link error during starting (IID) CC183: Dynamic link error during starting (IPF) CC184: Dynamic link error during starting (IMY) CC185: Dynamic link error during starting (SPF) CC186: Dynamic link error during starting (OAP) |
Rank | C |
Trouble detection condition | A dynamic link error occurs in the program on the CPU board due to an insufficient memory space available, a ROM fault, or other reason when the main power switch is turned ON. |
Trouble isolation | – |
Relevant electrical parts | -CPU board (CPUB) -Base board (BASEB) |
Procedure
- If the trouble code C-C172 has occurred, access [Service Mode] -> [System 2] -> [Image Controller Setting] and check to see if Others is set for image controller.
- If any of these is set, according to the kind of controller, select Controller 0 or Controller 1.
- If the trouble code “C-C180” has occurred, check to install the appropriate loadable device driver for an authentication unit which is installed to the MFP.
- When the appropriate loadable device driver is not installed, reinstall the appropriate loadable device driver.
- Check CPUB for proper installation and correct as necessary.
- Replace CPUB.
650i/550i (Part# AC74H02P03)
450i (Part# AC76H02P02) - Replace BASEB. (Part# AC74H02101)
- If the above actions do not solve the problem, contact KM.