CC174 (bizhub C554/C454)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | Dynamic link error during starting (AP4) |
Trouble code | CC174 |
Rank | C |
Detection timing | A dynamic link error occurs in the program on the MFP board due to an insufficient memory space available, a ROM fault, or other reason when the main power switch is turned ON. |
Trouble isolation | – |
Relevant electrical parts | MFP board (MFPB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | If the malfunction code C-C172 has occurred, access [Service Mode] -> [System 2] -> [Image Controller Setting] and check to see if Controller 2, Controller 3, or Others is set for [Image Controller Setting]. If any of these is set, according to the kind of controller, select Controller 0 or Controller 1. | – | – |
2 | If the malfunction code “C-C180” has occurred, check to install the appropriate loadable device driver for an authentication unit which is installed to the MFP.When the appropriate loadable device driver is not installed, reinstall the appropriate loadable device driver. | – | – |
3 | Replace MFPB (Part# A2XKH02004) | – | – |
4 | If the above actions do not solve the problem, contact KMBT. | – | – |
- Link to the layout drawings for related parts by each trouble code (S.103. C5372, C6901- C6903, CA051 – CA053, CC151, CC152, CC170 – CC186, CC191 – CC214, CC216, CD211, CD212, CD241, CD242, CD252 – CD271, CD401- CD412, CE001, CE003 – CE007, CE101, CE201, CE301 – CEEE1)
K3.15.12 (Link to the Field Service Manual)