Trouble type | CC182: Dynamic link error during starting (IID) |
Rank | C |
Trouble detection condition | A dynamic link error occurs in the program on the MFP board due to an insufficient memory space available, a ROM fault, or other reason when the main power switch is turned ON. |
Trouble isolation | – |
Relevant electrical parts | MFP board (MFPB) |
Procedure
- If the malfunction code C-C172 has occurred, access [Service Mode] -> [System 2] -> [Image Controller Setting] and check to see if Controller 1, or Others is set for [Image Controller Setting].
- If any of these is set, select Controller 0.
- If the malfunction code “C-C180” has occurred, check to install the appropriate loadable device driver for an authentication unit which is installed to the MFP.
- When the appropriate loadable device driver is not installed, reinstall the appropriate loadable device driver.
- Replace MFPB. (Part# A7AHH0201D)
- If the above actions do not solve the problem, contact KM.
K.3.17.8 (Link to the Field Service Manual)