How Can We Help?

CC183 (bizhub C364e/C284e/C224e)

You are here:

Contents

Trouble typeDynamic link error during starting (IPF)
Dynamic link error during starting (AP1)
Trouble codeCC183
RankC
Detection timingA dynamic link error occurs in the program on the MFP board due to an insufficient memory space available, a ROM fault, or other reason when the main power switch is turned ON.
Trouble isolation
Relevant electrical partsMFP board (MFPB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1If the malfunction code C-C172 has occurred, access [Service Mode] -> [System 2] -> [Image Controller Setting] and check to see if Controller 2, Controller 3, or Others is set for [Image Controller Setting].If any of these is set, according to the kind of controller, select Controller 0 or Controller 1.
2If the malfunction code “C-C180” has occurred, check to install the appropriate loadable device driver for an authentication unit which is installed to the MFP.When the appropriate loadable device driver is not installed, reinstall the appropriate loadable device driver.
3Replace MFPB (Part# A5C1H0200B)
4If the above actions do not solve the problem, contact KM.

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.15.11 (Link to the Field Service Manual)