CC186 (bizhub C3320i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | CC186: Dynamic link error during starting (OAP) |
Rank | C |
Trouble detection condition | A dynamic link error occurs in the program on the CPU board due to an insufficient memory space available, a ROM fault, or other reason when the main power switch is turned ON. |
Trouble isolation | – |
Relevant electrical parts | -CPU board (CPUB) -Base board (BASEB) |
Procedure
- If the trouble code “C-C180” has occurred, check to install the appropriate loadable device driver for an authentication unit which is installed to the MFP.
- When the appropriate loadable device driver is not installed, reinstall the appropriate loadable device driver.
- Check CPUB for proper installation and correct as necessary.
- Replace CPUB. (Part# AAJRH01005)
- Replace BASEB. (Part# A93EH02007)
- If the above actions do not solve the problem, contact KM.
L.3.16.7 (Link to the Field Service Manual)