CC191 (bizhub C287/C227)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | CC191: Setting parameter load error (LDR) |
Rank | C |
Trouble detection condition | Upon startup, the processing of the loadable device driver setting data file failed. -RAM disk file creation failed. -Reading from the flash ROM failed. -An error occurred in API of the authentication module. |
Trouble isolation | – |
Relevant electrical parts | MFP board (MFPB) |
Procedure
- Turn OFF the main power switch, wait for 10 sec., then turn the switch ON.
- Reinstall the loadable device driver.
- Rewrite the firmware.
- Replace MFPB. (Part# A797H02118)
K.3.17.10 (Link to the Field Service Manual)