CC191 (bizhub C759/C659)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | CC191: Setting parameter load error (LDR) | |
Rank | C | |
Trouble detection condition | Upon startup, the processing of the loadable device driver setting data file failed. | -RAM disk file creation failed. -Reading from the flash ROM failed. -An error occurred in API of the authentication module. |
Trouble isolation | – | |
Relevant electrical parts | MFP board (MFPB) |
Procedure
- Turn OFF the main power switch, wait for 10 sec., then turn the switch ON.
- Reinstall the loadable device driver.
- Rewrite the firmware.
- Replace MFPB. (Part# A8JEH02002)
L.3.17.12 (Link to the Field Service Manual)