CD004, CD00F (bizhub 4700i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | CD004: Storage access error (connection failure) CD00F: Storage data transfer error |
Rank | C |
Trouble detection condition | CD004: Unable to communicate between the storage and CPU board (CPUB). CD00F: Data transfer from the storage is faulty. |
Trouble isolation | – |
Relevant electrical parts | -microSD -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Check the microSD for proper installation and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Replace the microSD. (Contact Konica Minolta for replacement part# if needed)
- Replace CPUB. (Part# ACTAH01003)
- Replace BASEB. (Part# ACTAH02014)